NEW Vacuum Filter Holder Sets
All glass Vacuum Filter Holder Set, 47mm
This all-glass filter holder is used in particulate contamination analysis for filtering aqueous, organic, or corrosive liquids. It is also recommended for HPLC solvent filtration. Complete set includes a borosilicate glass funnel, anodized aluminum spring clamp, vacuum base with sintered disc, and ground joint flask. Membrane filters are not included. Parts are also available separately.
Specifications
This all-glass filter holder is used in particulate contamination analysis for filtering aqueous, organic, or corrosive liquids. It is also recommended for HPLC solvent filtration. Complete set includes a borosilicate glass funnel, anodized aluminum spring clamp, vacuum base with sintered disc, and ground joint flask. Membrane filters are not included. Parts are also available separately. Specifications
| Materials: Borosilicate glass funnel, base and tubulated cap; anodized aluminum spring clamp; fritted glass filter support |
Filtration Area: 9.6cm2 |
| Capacity: Funnel: 300ml Flask: 1000ml |
|
| Filter Diameter: 47mm |
Outlet Fitting: 6mm (1/4") O.D. tubulated cap sidearm to vacuum |
| Item # | Description | List Price |
|---|---|---|
| FHAG47 | Vacuum Filter Holder Set, 47mm | $370.03 |
| FHGF300 | Replacement Glass Funnel, 300ml | $60.00 |
| FHSC47 | Replacement Spring Clamp, 47mm | $64.26 |
| FHGBC47 | Replacement Glass Base and Cap, 47mm | $163.26 |
| FHFG1000 | Replacement Flask with Ground Glass Joints, 1000ml | $91.75 |
All-Glass Vacuum Filter Holder Set, 90mm
This all-glass filter holder is used in particulate contamination analysis for filtering aqueous, organic, or corrosive liquids. It is also recommended for HPLC solvent filtration. Complete set includes a borosilicate glass funnel, base and tubulated cap, anodized aluminum spring clamp, and PTFEcoated stainless steel screen. Membrane filters are not included. Parts are also available separately.
Specifications
This all-glass filter holder is used in particulate contamination analysis for filtering aqueous, organic, or corrosive liquids. It is also recommended for HPLC solvent filtration. Complete set includes a borosilicate glass funnel, base and tubulated cap, anodized aluminum spring clamp, and PTFEcoated stainless steel screen. Membrane filters are not included. Parts are also available separately. Specifications
| Materials: Borosilicate glass funnel, base and tubulated cap; anodized aluminum spring clamp; PTFE-coated stainless steel screen |
Capacity: Funnel: 1000ml |
| Filter Diameter: 90mm |
|
| Outlet Fitting: 6mm (1/4") O.D. tubulated cap sidearm to vacuum |
| Item # | Description | List Price |
|---|---|---|
| FHSS90 | Vacuum Filter Holder Set, 90mm | $718.62 |
| FHGF1000 | Replacement Glass Funnel, 1000ml | $125.68 |
| FHSC90 | Replacement Spring Clamp, 90mm | $129.70 |
| FHGBC90 | Replacement Glass Base and Cap, 90mm | $269.50 |
| FHSSR90 | Replacement Support Screen, Stainless, PTFE Coated, 90mm | $197.18 |
| FHGSP90 | Replacement Gasket, PTFE, 90mm | $8.48 |
| Optional Accessories | - | |
| FHFG1000 | Flask, 1000ml capacity, with Ground Glass Joints | $91.74 |
| FHBT2000 | Vacuum Bottle, 2000ml capacity, with Ground Glass Joints | $359.88 |
| FHBT5000 | Vacuum Bottle, 5000ml capacity, with Ground Glass Joints | $992.58 |
Microanalysis Vacuum Filter Holder Set, 25mm with Fritted Glass Filter Support
Designed for particulate or biological contamination analysis of small volumes using a vacuum filter. Includes a fritted glass filter support and No. 5 perforated silicone stopper for easy attachment to a vacuum filtering flask. Membrane filters are not included. Thick prefilters or laminated filters will not seal in this holder, and it is not autoclavable with membrane filters installed. Unlaminated PTFE or PVDF membranes are recommended for solvent applications.
Complete set includes a borosilicate glass funnel and base, fritted glass filter support, anodized aluminum spring clamp, and silicone stopper. Parts are also available separately.
Specifications
Designed for particulate or biological contamination analysis of small volumes using a vacuum filter. Includes a fritted glass filter support and No. 5 perforated silicone stopper for easy attachment to a vacuum filtering flask. Membrane filters are not included. Thick prefilters or laminated filters will not seal in this holder, and it is not autoclavable with membrane filters installed. Unlaminated PTFE or PVDF membranes are recommended for solvent applications.Complete set includes a borosilicate glass funnel and base, fritted glass filter support, anodized aluminum spring clamp, and silicone stopper. Parts are also available separately.
Specifications
| Materials: Borosilicate glass funnel and base; anodized aluminum spring clamp; fritted glass filter support; silicone stopper |
Capacity: Funnel: 15ml |
| Outlet Fitting: No. 5 perforated silicone stopper mounts in standard 125ml filtering flask |
Dimensions: Height: 15.2cm Diameter: 2.5cm |
| Filtration Area: 2.5cm2 |
Filter Diameter: 25mm |
| Item # | Description | List Price |
|---|---|---|
| FHMA25 | Microanalysis Vacuum Filter Holder Set, Fritted Glass, 25mm | $209.50 |
| FHGF15 | Replacement Glass Funnel, 15ml | $36.12 |
| FHSC25 | Replacement Spring Clamp, 25mm | $67.48 |
| FHGBS25 | Replacement Fritted Glass Base with Stopper, 25mm | $96.36 |
| FHSTS5 | Replacement Perforated Silicone Stopper, No. 5 | $9.64 |
| Optional Accessory | - | |
| FHFL125 | Vacuum Filtering Flask, 125ml capacity | $15.06 |

Designed for particulate or biological contamination analysis of small volumes using a vacuum filter. Includes a stainless steel screen filter support and No. 5 perforated silicone stopper for easy attachment to a vacuum filtering flask. Membrane filters are not included. Thick prefilters or laminated filters will not seal in this holder, and it is not autoclavable with membrane filters installed. Unlaminated PTFE or PVDF membranes are recommended for solvent applications.
Designed for bacteriological analysis of water using 47mm sterile membrane filters. Also applicable for analysis of suspended solids in water using 47mm depth filters. Complete set includes a borosilicate glass funnel and base, anodized aluminum spring clamp, and perforated silicone stopper. Parts are also available separately.
Designed for bacteriological analysis where it is necessary to sterilize the filter holder with the membrane filter in place. The glass surface is coated with PTFE to avoid filter damage and membrane adhesion during autoclaving. Complete set includes a PTFE-faced borosilicate glass funnel and PTFE-faced base, anodized aluminum spring clamp, and perforated silicone stopper. Parts are also available separately.
Designed for analyzing particulate contamination of hydraulic fluids and oils using gravimetric or particulate counting methods, and can be used in exfoliative cytology applications. Complete set includes a borosilicate glass funnel and base, anodized aluminum spring clamp, stainless steel support screen, PTFE gasket, and perforated silicone stopper. Parts are also available separately.